1. inv、sensor_avg 自動加入欄位
2. 修改逆變器歸檔sql
This commit is contained in:
parent
dcca7c4afc
commit
c6ea225956
@ -3289,6 +3289,20 @@ namespace SolarPower.Controllers
|
||||
}
|
||||
else
|
||||
{
|
||||
//檢查資料表是否有該欄位
|
||||
var check_inv_col = await powerStationRepository.CheckInvTableColumn(powerStation.SiteDB, powerStation.Code);
|
||||
var check_sensor_avg_col = await powerStationRepository.CheckSensorAvgTableColumn(powerStation.SiteDB, powerStation.Code);
|
||||
|
||||
if (check_inv_col != 1)
|
||||
{
|
||||
await powerStationRepository.AlertColInvTableColumn(powerStation.SiteDB, powerStation.Code);
|
||||
}
|
||||
|
||||
if (check_sensor_avg_col != 1)
|
||||
{
|
||||
await powerStationRepository.AlertColSensoravgTableColumn(powerStation.SiteDB, powerStation.Code);
|
||||
}
|
||||
|
||||
await powerStationRepository.StationStatus(Id, 1);
|
||||
await powerStationRepository.StationStatus(Id, 1, powerStation.SiteDB + ".");
|
||||
apiResult.Msg = "電站啟用成功";
|
||||
|
||||
@ -2890,19 +2890,20 @@ namespace SolarPower.Repository.Implement
|
||||
var sql = $@"SELECT
|
||||
s.TIMESTAMP,
|
||||
s.INVERTERID,
|
||||
a.KWH,
|
||||
s.KWH,
|
||||
s.TODAYKWH,
|
||||
i.Capacity,
|
||||
a.KWH/(i.Capacity/4) AS KWHKWP
|
||||
s.KWH/(i.Capacity/4) AS KWHKWP
|
||||
FROM (SELECT
|
||||
MAX(FROM_UNIXTIME(sub_inv.TIMESTAMP/1000, '%Y-%m-%d %H:%i')) AS TIMESTAMP,
|
||||
sub_inv.INVERTERID,
|
||||
SUM(sub_inv.WH)/1000 AS KWH,
|
||||
MAX(sub_inv.TODAYKWH) AS TODAYKWH
|
||||
FROM {table_name} sub_inv
|
||||
WHERE FROM_UNIXTIME(sub_inv.TIMESTAMP/1000, '%Y-%m-%d %H:%i') BETWEEN @StartDateTime AND @EndDateTime
|
||||
AND sub_inv.INVERTERID IN @InverterIds
|
||||
GROUP BY sub_inv.INVERTERID) s
|
||||
LEFT JOIN (
|
||||
/*LEFT JOIN (
|
||||
SELECT MAX(FROM_UNIXTIME(sub_inv.TIMESTAMP/1000, '%Y-%m-%d %H:%i')) AS TIMESTAMP,
|
||||
sub_inv.INVERTERID,
|
||||
SUM(sub_inv.WH)/1000 AS KWH
|
||||
@ -2910,10 +2911,10 @@ namespace SolarPower.Repository.Implement
|
||||
WHERE FROM_UNIXTIME(sub_inv.TIMESTAMP/1000, '%Y-%m-%d %H:%i') BETWEEN @StartDateTime AND @EndDateTime
|
||||
AND sub_inv.INVERTERID IN @InverterIds
|
||||
GROUP BY sub_inv.INVERTERID) a
|
||||
ON s.TIMESTAMP = a.TIMESTAMP AND s.INVERTERID = a. INVERTERID
|
||||
ON s.TIMESTAMP = a.TIMESTAMP AND s.INVERTERID = a. INVERTERID*/
|
||||
LEFT JOIN {db_name}.inverter i ON s.INVERTERID = REPLACE(i.InverterId, 's', '');";
|
||||
|
||||
result = (await conn.QueryAsync<InverterHistory>(sql, new { StartDateTime = stratDateTime, EndDateTime = dateTime, InverterIds = inverterIds })).ToList();
|
||||
result = (await conn.QueryAsync<InverterHistory>(sql, new { StartDateTime = stratDateTime, EndDateTime = dateTime, InverterIds = inverterIds }, commandTimeout: 300)).ToList();
|
||||
}
|
||||
catch (Exception exception)
|
||||
{
|
||||
@ -3008,14 +3009,14 @@ namespace SolarPower.Repository.Implement
|
||||
AVG(s.RA3) AS RA3,
|
||||
AVG(s.RA4) AS RA4,
|
||||
AVG(s.RA5) AS RA5,
|
||||
a.KWH,
|
||||
SUM(s.WH)/1000 AS KWH,
|
||||
MAX(s.TODAYKWH) AS TODAYKWH,
|
||||
MAX(s.TOTALKWH) AS TOTALKWH,
|
||||
i.Capacity,
|
||||
(a.KWH/i.Capacity) AS KWHKWP
|
||||
((SUM(s.WH)/1000) / i.Capacity) AS KWHKWP
|
||||
FROM {table_name} s
|
||||
-- 取得該時間區間的KWH
|
||||
LEFT JOIN (
|
||||
/*LEFT JOIN (
|
||||
SELECT
|
||||
FROM_UNIXTIME(inv.TIMESTAMP/1000, '%Y-%m-%d %H') AS TIMESTAMP,
|
||||
inv.INVERTERID,
|
||||
@ -3024,26 +3025,26 @@ namespace SolarPower.Repository.Implement
|
||||
WHERE DATE_FORMAT(FROM_UNIXTIME(inv.TIMESTAMP/1000), '%Y-%m-%d %H') = @DateTime
|
||||
AND inv.INVERTERID IN @InverterIds
|
||||
GROUP BY FROM_UNIXTIME(inv.TIMESTAMP/1000, '%Y-%m-%d %H'), inv.INVERTERID) a
|
||||
ON FROM_UNIXTIME(s.TIMESTAMP/1000, '%Y-%m-%d %H') = a.TIMESTAMP AND s.INVERTERID = a. INVERTERID
|
||||
ON FROM_UNIXTIME(s.TIMESTAMP/1000, '%Y-%m-%d %H') = a.TIMESTAMP AND s.INVERTERID = a. INVERTERID*/
|
||||
-- 取得整點值PR
|
||||
LEFT JOIN (
|
||||
SELECT
|
||||
FROM_UNIXTIME(inv.TIMESTAMP/1000, '%Y-%m-%d %H') AS TIMESTAMP,
|
||||
inv.CrdTime AS TIMESTAMP,
|
||||
inv.INVERTERID,
|
||||
inv.PR
|
||||
FROM {table_name} inv
|
||||
WHERE DATE_FORMAT(FROM_UNIXTIME(inv.TIMESTAMP/1000), '%Y-%m-%d %H:%i') = CONCAT(@DateTime, ':55')
|
||||
WHERE left(inv.CrdTime, 16) = CONCAT(@DateTime, ':55')
|
||||
AND inv.INVERTERID IN @InverterIds
|
||||
GROUP BY FROM_UNIXTIME(inv.TIMESTAMP/1000, '%Y-%m-%d %H'), inv.INVERTERID) inv_pr
|
||||
ON FROM_UNIXTIME(s.TIMESTAMP/1000, '%Y-%m-%d %H') = inv_pr.TIMESTAMP AND s.INVERTERID = inv_pr. INVERTERID
|
||||
GROUP BY left(inv.CrdTime, 13), inv.INVERTERID) inv_pr
|
||||
ON left(s.CrdTime, 13) = inv_pr.TIMESTAMP AND s.INVERTERID = inv_pr. INVERTERID
|
||||
-- 取得逆變器容量
|
||||
LEFT JOIN {db_name}.inverter i ON s.INVERTERID = i.InverterId
|
||||
WHERE FROM_UNIXTIME(s.TIMESTAMP/1000, '%Y-%m-%d %H') = @DateTime
|
||||
WHERE left(s.CrdTime, 13) = @DateTime
|
||||
AND s.INVERTERID IN @InverterIds
|
||||
GROUP BY DATE_FORMAT(FROM_UNIXTIME(s.TIMESTAMP/1000), '%Y-%m-%d %H'), s.INVERTERID
|
||||
GROUP BY left(s.CrdTime, 13), s.INVERTERID
|
||||
";
|
||||
|
||||
result = (await conn.QueryAsync<InverterHistory>(sql, new { DateTime = dateTime, InverterIds = inverterIds })).ToList();
|
||||
result = (await conn.QueryAsync<InverterHistory>(sql, new { DateTime = dateTime, InverterIds = inverterIds }, commandTimeout: 300)).ToList();
|
||||
}
|
||||
catch (Exception exception)
|
||||
{
|
||||
@ -4467,7 +4468,7 @@ namespace SolarPower.Repository.Implement
|
||||
inv.RA5
|
||||
FROM {table_name} inv
|
||||
LEFT JOIN (select * from {sensor_table_name} where TIMESTAMP between @start_timestamp and @end_timestamp)sen
|
||||
ON FROM_UNIXTIME(inv.TIMESTAMP/1000, '%Y-%m-%d %H:%i') = FROM_UNIXTIME(sen.TIMESTAMP/1000, '%Y-%m-%d %H:%i')
|
||||
ON inv.CrdTime = sen.CrdTime
|
||||
-- LEFT JOIN {sensor_table_name} sen ON FROM_UNIXTIME(inv.TIMESTAMP/1000, '%Y-%m-%d %H:%i') = FROM_UNIXTIME(sen.TIMESTAMP/1000, '%Y-%m-%d %H:%i')
|
||||
LEFT JOIN {entity.SiteDB}.inverter i ON inv.INVERTERID = i.InverterId
|
||||
WHERE inv.`TIMESTAMP` between @start_timestamp and @end_timestamp
|
||||
@ -5837,5 +5838,129 @@ namespace SolarPower.Repository.Implement
|
||||
return resule;
|
||||
}
|
||||
}
|
||||
|
||||
public async Task<int> CheckInvTableColumn (string dbname, string code)
|
||||
{
|
||||
|
||||
using (IDbConnection conn = this._databaseHelper.GetConnection())
|
||||
{
|
||||
conn.Open();
|
||||
|
||||
var resule = 0;
|
||||
try
|
||||
{
|
||||
var sql = $@"SELECT count(*) FROM information_schema.columns WHERE table_schema='{dbname}' AND table_name = 's{code}01_inv' AND column_name = 'CrdTime'";
|
||||
resule = await conn.QueryFirstOrDefaultAsync<int>(sql);
|
||||
|
||||
}
|
||||
catch (Exception exception)
|
||||
{
|
||||
throw exception;
|
||||
}
|
||||
finally
|
||||
{
|
||||
conn.Close();
|
||||
}
|
||||
|
||||
return resule;
|
||||
}
|
||||
}
|
||||
|
||||
public async Task<int> CheckSensorAvgTableColumn(string dbname, string code)
|
||||
{
|
||||
|
||||
using (IDbConnection conn = this._databaseHelper.GetConnection())
|
||||
{
|
||||
conn.Open();
|
||||
|
||||
var resule = 0;
|
||||
try
|
||||
{
|
||||
var sql = $@"SELECT count(*) FROM information_schema.columns WHERE table_schema='{dbname}' AND table_name = 's{code}01_sensoravg' AND column_name = 'CrdTime'";
|
||||
resule = await conn.QueryFirstOrDefaultAsync<int>(sql);
|
||||
}
|
||||
catch (Exception exception)
|
||||
{
|
||||
throw exception;
|
||||
}
|
||||
finally
|
||||
{
|
||||
conn.Close();
|
||||
}
|
||||
|
||||
return resule;
|
||||
}
|
||||
}
|
||||
|
||||
public async Task AlertColInvTableColumn(string dbname, string code)
|
||||
{
|
||||
using (IDbConnection conn = this._databaseHelper.GetConnection())
|
||||
{
|
||||
conn.Open();
|
||||
|
||||
try
|
||||
{
|
||||
var sql = $@"ALTER TABLE {dbname}.s{code}01_inv ADD COLUMN CrdTime datetime;
|
||||
use {dbname};
|
||||
create trigger trg01_s{code}01_inv
|
||||
before insert on {dbname}.s{code}01_inv
|
||||
FOR EACH ROW
|
||||
begin
|
||||
set new.CrdTime = FROM_UNIXTIME(new.`TIMESTAMP`/1000,'%Y-%m-%d %H:%i');
|
||||
end;
|
||||
use solar_master;
|
||||
|
||||
update {dbname}.s{code}01_inv set crdtime = FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H:%i');
|
||||
|
||||
CREATE INDEX IDX02_s{code}01 ON {dbname}.s{code}01_inv(Inverterid, CrdTime);";
|
||||
|
||||
await conn.ExecuteAsync(sql);
|
||||
}
|
||||
catch (Exception exception)
|
||||
{
|
||||
throw exception;
|
||||
}
|
||||
finally
|
||||
{
|
||||
conn.Close();
|
||||
}
|
||||
|
||||
}
|
||||
}
|
||||
|
||||
public async Task AlertColSensoravgTableColumn(string dbname, string code)
|
||||
{
|
||||
using (IDbConnection conn = this._databaseHelper.GetConnection())
|
||||
{
|
||||
conn.Open();
|
||||
|
||||
try
|
||||
{
|
||||
var sql = $@"ALTER TABLE {dbname}.s{code}01_sensoravg ADD COLUMN CrdTime datetime;
|
||||
use {dbname};
|
||||
create trigger trg01_s{code}01_sensoravg
|
||||
before insert on {dbname}.s{code}01_sensoravg
|
||||
FOR EACH ROW
|
||||
begin
|
||||
set new.CrdTime = FROM_UNIXTIME(new.`TIMESTAMP`/1000,'%Y-%m-%d %H:%i');
|
||||
end;
|
||||
use solar_master;
|
||||
|
||||
update {dbname}.s{code}01_sensoravg set crdtime = FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H:%i');
|
||||
|
||||
CREATE INDEX IDX{code}01_sensoravg ON {dbname}.s{code}01_sensoravg(CrdTime);";
|
||||
await conn.ExecuteAsync(sql);
|
||||
}
|
||||
catch (Exception exception)
|
||||
{
|
||||
throw exception;
|
||||
}
|
||||
finally
|
||||
{
|
||||
conn.Close();
|
||||
}
|
||||
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@ -608,5 +608,9 @@ namespace SolarPower.Repository.Interface
|
||||
Task UpdateInvStatus(string siteDB, List<string> codes, List<string> inverterIds = null, byte status = 0);
|
||||
Task<List<InvStatusErr>> GetInvStatusErr(List<string> codes);
|
||||
Task<Check4table> Check4table(string code, string dbname);
|
||||
Task<int> CheckInvTableColumn(string dbname, string code);
|
||||
Task<int> CheckSensorAvgTableColumn(string dbname, string code);
|
||||
Task AlertColInvTableColumn(string dbname, string code);
|
||||
Task AlertColSensoravgTableColumn(string dbname, string code);
|
||||
}
|
||||
}
|
||||
|
||||
Loading…
Reference in New Issue
Block a user