402 lines
24 KiB
C#
402 lines
24 KiB
C#
using System;
|
||
using System.Collections.Generic;
|
||
using System.Text;
|
||
using MySql.Data.MySqlClient;
|
||
using Dapper;
|
||
using solarApp.Model;
|
||
using System.Configuration;
|
||
using System.Threading.Tasks;
|
||
using Microsoft.Extensions.Logging;
|
||
|
||
namespace solarApp.Service
|
||
{
|
||
public class procInvSvc
|
||
{
|
||
string Connection1 = string.Empty;
|
||
ILogger _logger;
|
||
|
||
public procInvSvc(string Connection_parame = null, ILogger logger = null)
|
||
{
|
||
if (!string.IsNullOrEmpty(Connection_parame))
|
||
{
|
||
Connection1 = Connection_parame;
|
||
}
|
||
else
|
||
{
|
||
Connection1 = ConfigurationManager.ConnectionStrings["mySql"].ConnectionString;
|
||
}
|
||
|
||
if (logger != null)
|
||
{
|
||
_logger = logger;
|
||
}
|
||
}
|
||
|
||
public string _siteID { get; set; }
|
||
public string _siteDB { get; set; }
|
||
public string _siteID01 { get; set; }
|
||
public string _date1 { get; set; }
|
||
//public string _date2 { get; set; }
|
||
public string _powerStationID { get; set; }
|
||
|
||
|
||
public bool clearData()
|
||
{
|
||
bool result = false;
|
||
try
|
||
{
|
||
using (MySqlConnection conn = new MySqlConnection(Connection1))
|
||
{
|
||
conn.Open();
|
||
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】開始執行[{0}]在{1}逆變器清除資料表的資料", _siteID, _date1);
|
||
}
|
||
|
||
string sql = @"
|
||
delete from inverter_history_15min where powerstationID = @powerStationID and DATE_FORMAT(`TIMESTAMP`,'%Y-%m-%d') = @date1;
|
||
delete from inverter_history_hour where powerstationID = @powerStationID and DATE_FORMAT(`TIMESTAMP`,'%Y-%m-%d') = @date1;
|
||
delete from inverter_history_day where powerstationID = @powerStationID and DATE_FORMAT(`TIMESTAMP`,'%Y-%m-%d') = @date1;
|
||
delete from inverter_history_month where powerstationID = @powerStationID and left(`TIMESTAMP`, 7) = left(@date1, 7) ;";
|
||
var ds = conn.Execute(sql, new { date1 = _date1, PowerStationID = _powerStationID });
|
||
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】執行完成[{0}]在{1}逆變器清除資料表的資料", _siteID, _date1);
|
||
}
|
||
|
||
conn.Close();
|
||
}
|
||
result = true;
|
||
}
|
||
catch (Exception ex)
|
||
{
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器清除資料表的資料", _siteID, _date1);
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器清除資料表的資料 - [Exception]:{2}", _siteID, _date1, ex.ToString());
|
||
}
|
||
throw ex;
|
||
}
|
||
return result;
|
||
}
|
||
|
||
public bool archiveData(string siteID, string date1)
|
||
{
|
||
bool result = false;
|
||
try
|
||
{
|
||
_siteID = siteID;
|
||
_date1 = date1;
|
||
get_siteInfo();
|
||
clearData();
|
||
insert_inv();
|
||
result = true;
|
||
}
|
||
catch (Exception ex)
|
||
{
|
||
throw ex;
|
||
}
|
||
return result;
|
||
}
|
||
public bool get_siteInfo()
|
||
{
|
||
bool result = false;
|
||
try
|
||
{
|
||
using (MySqlConnection conn = new MySqlConnection(Connection1))
|
||
{
|
||
conn.Open();
|
||
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】開始執行[{0}]在{1}逆變器取得電站編號", _siteID, _date1);
|
||
}
|
||
|
||
#region 取得 PowerStationID
|
||
string sql = @" select id , `code` siteID, siteDB, `name` siteName
|
||
from solar_master.power_station where `code` = @siteID";
|
||
var ds = conn.Query<station_list>(sql, new { siteID = _siteID }).AsList<station_list>();
|
||
foreach (var item in ds)
|
||
{
|
||
_powerStationID = item.id;
|
||
_siteDB = item.SiteDB;
|
||
_siteID01 = item.SiteID + "01";
|
||
}
|
||
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】執行完成[{0}]在{1}逆變器取得電站編號 - {2}", _siteID, _date1, _powerStationID);
|
||
}
|
||
|
||
#endregion
|
||
conn.Close();
|
||
}
|
||
result = true;
|
||
}
|
||
catch (Exception ex)
|
||
{
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器取得電站編號", _siteID, _date1);
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器取得電站編號 - [Exception]:{2}", _siteID, _date1, ex.ToString());
|
||
}
|
||
|
||
throw ex;
|
||
}
|
||
return result;
|
||
}
|
||
bool insert_inv()
|
||
{
|
||
bool result = false;
|
||
try
|
||
{
|
||
using (MySqlConnection conn = new MySqlConnection(Connection1))
|
||
{
|
||
conn.Open();
|
||
string ss = @"SET SESSION sql_mode=(SELECT REPLACE(@@sql_mode,'ONLY_FULL_GROUP_BY,',''));";
|
||
conn.Execute(ss);
|
||
|
||
string sql = string.Empty;
|
||
#region 15 min
|
||
try
|
||
{
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】開始執行[{0}]在{1}逆變器15min補償", _siteID, _date1);
|
||
}
|
||
|
||
sql = @"
|
||
INSERT INTO solar_master.inverter_history_15min( PowerStationId, TIMESTAMP, INVERTERID, KWH, TODAYKWH, KWHKWP)
|
||
select PowerStationId, reportdate, a.inverterid, KWH, TODAYKWH, (kwh/(capacity/4)) kwpkwp from
|
||
(
|
||
select @PowerStationId PowerStationId, CONCAT(FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H'), ':00:00')reportdate, inverterid,
|
||
(sum(WH)/1000) KWH, max(TODAYKWH) TODAYKWH
|
||
from " + _siteDB + ".s" + _siteID01 + @"_inv
|
||
where FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d') = @date1 and right(FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H:%i') , 2) between '00' and '10'
|
||
group by FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H') , inverterid
|
||
union
|
||
select @PowerStationId PowerStationId, CONCAT(FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H'), ':15:00')reportdate, inverterid,
|
||
(sum(WH)/1000) KWH, max(TODAYKWH) TODAYKWH
|
||
from " + _siteDB + ".s" + _siteID01 + @"_inv
|
||
where FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d') = @date1 and right(FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H:%i') , 2) between '15' and '25'
|
||
group by FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H') , inverterid
|
||
union
|
||
select @PowerStationId PowerStationId, CONCAT(FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H'), ':30:00')reportdate, inverterid,
|
||
(sum(WH)/1000) KWH, max(TODAYKWH) TODAYKWH
|
||
from " + _siteDB + ".s" + _siteID01 + @"_inv
|
||
where FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d') = @date1 and right(FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H:%i') , 2) between '30' and '40'
|
||
group by FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H') , inverterid
|
||
union
|
||
select @PowerStationId PowerStationId, CONCAT(FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H'), ':45:00')reportdate, inverterid,
|
||
(sum(WH)/1000) KWH, max(TODAYKWH) TODAYKWH
|
||
from " + _siteDB + ".s" + _siteID01 + @"_inv
|
||
where FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d') = @date1 and right(FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H:%i') , 2) between '45' and '55'
|
||
group by FROM_UNIXTIME(`TIMESTAMP`/1000,'%Y-%m-%d %H') , inverterid
|
||
) a join " + _siteDB + @".inverter b on a.inverterid = b.inverterid";
|
||
var ds = conn.Execute(sql, new { date1 = _date1, PowerStationID = _powerStationID });
|
||
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】執行完成[{0}]在{1}逆變器15min補償", _siteID, _date1);
|
||
}
|
||
}
|
||
catch (Exception ex)
|
||
{
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器15min補償", _siteID, _date1);
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器15min補償 - [Exception]:{2}", _siteID, _date1, ex.ToString());
|
||
throw ex;
|
||
}
|
||
#endregion
|
||
|
||
#region hour
|
||
try
|
||
{
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】開始執行[{0}]在{1}逆變器hour補償", _siteID, _date1);
|
||
}
|
||
|
||
sql = @"
|
||
insert into solar_master.inverter_history_hour (PowerStationId, INVERTERID, TIMESTAMP, Irradiance, AC1V, AC1A, AC1W, AC1F, AC1WH, AC2V, AC2A, AC2W, AC2F, AC2WH,
|
||
AC3V, AC3A, AC3W, AC3F, AC3WH, DC1V, DC1A, DC1W, DC1WH, DC2V, DC2A, DC2W, DC2WH, DC3V, DC3A, DC3W, DC3WH, DC4V, DC4A, DC4W, DC4WH, DC5V, DC5A, DC5W, DC5WH,
|
||
PR, RA1, RA2, RA3, RA4, RA5, DCKW, ACKW, KWH, TODAYKWH, TOTALKWH, KWHKWP)
|
||
|
||
SELECT @powerstationID powerStationID, a.INVERTERID, a.reportDate, IFNULL(Irradiance, 0), a.AC1V, a.AC1A, a.AC1W, a.AC1F, a.AC1WH, a.AC2V, a.AC2A, a.AC2W, a.AC2F, a.AC2WH,
|
||
a.AC3V, a.AC3A, a.AC3W, a.AC3F, a.AC3WH, a.DC1V, a.DC1A, a.DC1W, a.DC1WH, a.DC2V, a.DC2A, a.DC2W, a.DC2WH, a.DC3V, a.DC3A, a.DC3W,
|
||
a.DC3WH, a.DC4V, a.DC4A, a.DC4W, a.DC4WH, a.DC5V, a.DC5A, a.DC5W, a.DC5WH,
|
||
inv_pr.PR, a.RA1, a.RA2, a.RA3, a.RA4, a.RA5, ((DC1W + DC2W + DC3W + DC4W+ DC5W) / 1000) DCKW,
|
||
((AC1W + AC2W + AC3W) / 1000) ACKW, a.KWH, a.TODAYKWH, a.TOTALKWH, (a.KWH / i.Capacity) AS KWHKWP
|
||
from
|
||
( -- 取得該時間區間的KWH
|
||
SELECT concat(FROM_UNIXTIME(a.TIMESTAMP/1000,'%Y-%m-%d %H'), ':00:00') reportDate, a.INVERTERID,
|
||
AVG(a.AC1V) AS AC1V, AVG(a.AC1A) AS AC1A, round(SUM(a.AC1W), 5) AS AC1W, AVG(a.AC1F) AS AC1F, SUM(a.AC1WH) AS AC1WH, AVG(a.AC2V) AS AC2V,
|
||
AVG(a.AC2A) AS AC2A, round(SUM(a.AC2W), 5) AS AC2W, AVG(a.AC2F) AS AC2F, SUM(a.AC2WH) AS AC2WH,AVG(a.AC3V) AS AC3V, AVG(a.AC3A) AS AC3A,
|
||
round(SUM(a.AC3W),5) AS AC3W, AVG(a.AC3F) AS AC3F, SUM(a.AC3WH) AS AC3WH, AVG(a.DC1V) AS DC1V, AVG(a.DC1A) AS DC1A, SUM(a.DC1W) AS DC1W,
|
||
SUM(a.DC1WH) AS DC1WH, AVG(a.DC2V) AS DC2V, AVG(a.DC2A) AS DC2A, SUM(a.DC2W) AS DC2W, SUM(a.DC2WH) AS DC2WH, AVG(a.DC3V) AS DC3V,
|
||
AVG(a.DC3A) AS DC3A, AVG(a.DC3W) AS DC3W, AVG(a.DC3WH) AS DC3WH, AVG(a.DC4V) AS DC4V, AVG(a.DC4A) AS DC4A, SUM(a.DC4W) AS DC4W,
|
||
SUM(a.DC4WH) AS DC4WH,AVG(a.DC5V) AS DC5V, AVG(a.DC5A) AS DC5A, SUM(a.DC5W) AS DC5W, SUM(a.DC5WH) AS DC5WH,
|
||
AVG(a.RA1) AS RA1, AVG(a.RA2) AS RA2, AVG(a.RA3) AS RA3,
|
||
AVG(a.RA4) AS RA4, AVG(a.RA5) AS RA5, MAX(a.TODAYKWH) AS TODAYKWH, MAX(a.TOTALKWH) AS TOTALKWH, (SUM(a.WH)/1000) AS KWH
|
||
FROM " + _siteDB + ".s" + _siteID01 + @"_inv a
|
||
WHERE left(FROM_UNIXTIME(a.TIMESTAMP / 1000, '%Y-%m-%d'), 10) = @date1
|
||
GROUP BY left(FROM_UNIXTIME(a.TIMESTAMP/ 1000, '%Y-%m-%d %H'), 13), a.INVERTERID
|
||
) a
|
||
LEFT JOIN( -- 取得整點值PR
|
||
SELECT concat(FROM_UNIXTIME(inv.TIMESTAMP/1000,'%Y-%m-%d %H'), ':00:00') AS reportDate, inv.INVERTERID, inv.PR
|
||
FROM " + _siteDB + ".s" + _siteID01 + @"_inv inv
|
||
WHERE left(DATE_FORMAT(FROM_UNIXTIME(inv.TIMESTAMP / 1000), '%Y-%m-%d %H:%i'), 10) = @date1
|
||
and right(DATE_FORMAT(FROM_UNIXTIME(inv.TIMESTAMP / 1000), '%Y-%m-%d %H:%i'), 2) = '55'
|
||
GROUP BY FROM_UNIXTIME(inv.TIMESTAMP/ 1000, '%Y-%m-%d %H'), inv.INVERTERID
|
||
) inv_pr
|
||
ON a.reportDate = inv_pr.reportDate AND a.INVERTERID = inv_pr.INVERTERID
|
||
-- 取得逆變器容量
|
||
LEFT JOIN " + _siteDB + @".inverter i ON a.INVERTERID = i.InverterId
|
||
-- 取日照度 ---------------------
|
||
left join (
|
||
select concat(DATE_FORMAT(`TIMESTAMP`,'%Y-%m-%d %H'), ':00:00') AS reportDate, Irradiance
|
||
from sensor_history_hour a
|
||
where powerstationID = @powerstationID and DATE_FORMAT(`TIMESTAMP`,'%Y-%m-%d') = @date1
|
||
)irr on a.reportDate = irr.reportDate
|
||
order by a.INVERTERID, a.reportDate;";
|
||
int ct = conn.Execute(sql, new { date1 = _date1, PowerStationID = _powerStationID });
|
||
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】執行完成[{0}]在{1}逆變器hour補償", _siteID, _date1);
|
||
}
|
||
}
|
||
catch (Exception ex)
|
||
{
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器hour補償", _siteID, _date1);
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器hour補償 - [Exception]:{2}", _siteID, _date1, ex.ToString());
|
||
throw ex;
|
||
}
|
||
|
||
#endregion hour
|
||
|
||
#region day
|
||
try
|
||
{
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】開始執行[{0}]在{1}逆變器day補償", _siteID, _date1);
|
||
}
|
||
|
||
sql = @"
|
||
INSERT INTO solar_master.inverter_history_day(PowerStationId, INVERTERID, TIMESTAMP, Irradiance, AC1V, AC1A, AC1W, AC1F, AC1WH, AC2V, AC2A, AC2W, AC2F, AC2WH,
|
||
AC3V, AC3A, AC3W, AC3F, AC3WH, DC1V, DC1A, DC1W, DC1WH, DC2V, DC2A, DC2W, DC2WH, DC3V, DC3A, DC3W,
|
||
DC3WH, DC4V, DC4A, DC4W, DC4WH, DC5V, DC5A, DC5W, DC5WH, PR, RA1, RA2, RA3, RA4, RA5, `DCKW`, `ACKW`, KWH, TODAYKWH, TOTALKWH, KWHKWP)
|
||
|
||
SELECT @powerStationID powerStationID, a.INVERTERID, concat(a.reportDate,' 00:00:00') reportDate, IFNULL(Irradiance, 0), a.AC1V, a.AC1A, a.AC1W, a.AC1F, a.AC1WH, a.AC2V, a.AC2A, a.AC2W, a.AC2F, a.AC2WH,
|
||
a.AC3V, a.AC3A, a.AC3W, a.AC3F, a.AC3WH, a.DC1V, a.DC1A, a.DC1W, a.DC1WH, a.DC2V, a.DC2A, a.DC2W, a.DC2WH, a.DC3V, a.DC3A, a.DC3W,
|
||
a.DC3WH, a.DC4V, a.DC4A, a.DC4W, a.DC4WH, a.DC5V, a.DC5A, a.DC5W, a.DC5WH, a.PR, a.RA1, a.RA2, a.RA3, a.RA4, a.RA5,
|
||
DCKW, ACKW, a.KWH, a.TODAYKWH, a.TOTALKWH, (a.KWH / i.Capacity) AS KWHKWP
|
||
from
|
||
( -- 取得該時間區間的KWH
|
||
SELECT DATE_FORMAT(a.TIMESTAMP, '%Y-%m-%d') AS reportDate, a.INVERTERID,
|
||
AVG(a.AC1V) AS AC1V, AVG(a.AC1A) AS AC1A, SUM(a.AC1W) AS AC1W, AVG(a.AC1F) AS AC1F, SUM(a.AC1WH) AS AC1WH, AVG(a.AC2V) AS AC2V,
|
||
AVG(a.AC2A) AS AC2A, SUM(a.AC2W) AS AC2W, AVG(a.AC2F) AS AC2F, SUM(a.AC2WH) AS AC2WH,AVG(a.AC3V) AS AC3V, AVG(a.AC3A) AS AC3A,
|
||
SUM(a.AC3W) AS AC3W, AVG(a.AC3F) AS AC3F, SUM(a.AC3WH) AS AC3WH, AVG(a.DC1V) AS DC1V, AVG(a.DC1A) AS DC1A, SUM(a.DC1W) AS DC1W,
|
||
SUM(a.DC1WH) AS DC1WH, AVG(a.DC2V) AS DC2V, AVG(a.DC2A) AS DC2A, SUM(a.DC2W) AS DC2W, SUM(a.DC2WH) AS DC2WH, AVG(a.DC3V) AS DC3V,
|
||
AVG(a.DC3A) AS DC3A, AVG(a.DC3W) AS DC3W, AVG(a.DC3WH) AS DC3WH, AVG(a.DC4V) AS DC4V, AVG(a.DC4A) AS DC4A, SUM(a.DC4W) AS DC4W,
|
||
SUM(a.DC4WH) AS DC4WH,AVG(a.DC5V) AS DC5V, AVG(a.DC5A) AS DC5A, SUM(a.DC5W) AS DC5W, SUM(a.DC5WH) AS DC5WH, max(PR) AS PR,
|
||
AVG(a.RA1) AS RA1, AVG(a.RA2) AS RA2, AVG(a.RA3) AS RA3, AVG(a.RA4) AS RA4, AVG(a.RA5) AS RA5, avg(DCKW) as DCKW, avg(ACKW) as ACKW,
|
||
MAX(a.TODAYKWH) AS TODAYKWH, MAX(a.TOTALKWH) AS TOTALKWH, SUM(a.KWH) AS KWH
|
||
FROM solar_master.inverter_history_hour a
|
||
WHERE powerstationID = @powerstationID and DATE_FORMAT(a.TIMESTAMP, '%Y-%m-%d') = @date1
|
||
GROUP BY DATE_FORMAT(a.TIMESTAMP, '%Y-%m-%d'), a.INVERTERID
|
||
) a
|
||
LEFT JOIN " + _siteDB + @".inverter i ON a.INVERTERID = i.InverterId
|
||
-- 取日照度 ----------------------
|
||
left join (
|
||
select DATE_FORMAT(a.TIMESTAMP, '%Y-%m-%d') AS reportDate, Irradiance
|
||
from sensor_history_day a
|
||
where powerstationID = @powerstationID and DATE_FORMAT(a.TIMESTAMP, '%Y-%m-%d') = @date1 and Irradiance <> 0 limit 1
|
||
)irr on a.reportDate = irr.reportDate ;";
|
||
conn.Execute(sql, new { date1 = _date1, PowerStationID = _powerStationID });
|
||
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】執行完成[{0}]在{1}逆變器day補償", _siteID, _date1);
|
||
}
|
||
}
|
||
catch (Exception ex)
|
||
{
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器day補償", _siteID, _date1);
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器day補償 - [Exception]:{2}", _siteID, _date1, ex.ToString());
|
||
throw ex;
|
||
}
|
||
#endregion day
|
||
|
||
#region month
|
||
try
|
||
{
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】開始執行[{0}]在{1}逆變器month補償", _siteID, _date1);
|
||
}
|
||
|
||
sql = @"
|
||
delete from inverter_history_month where powerstationID = @powerStationID and left(`TIMESTAMP`, 7) = left(@date1, 7) ;
|
||
|
||
INSERT INTO solar_master.inverter_history_month (PowerStationId, INVERTERID, TIMESTAMP, Irradiance, AC1V, AC1A, AC1W, AC1F, AC1WH, AC2V, AC2A, AC2W, AC2F, AC2WH,
|
||
AC3V, AC3A, AC3W, AC3F, AC3WH, DC1V, DC1A, DC1W, DC1WH, DC2V, DC2A, DC2W, DC2WH, DC3V, DC3A, DC3W,
|
||
DC3WH, DC4V, DC4A, DC4W, DC4WH, DC5V, DC5A, DC5W, DC5WH, PR, RA1, RA2, RA3, RA4, RA5, `DCKW`, `ACKW`, KWH, TODAYKWH, TOTALKWH, KWHKWP)
|
||
|
||
SELECT @powerStationID powerStationID, a.INVERTERID, concat(a.reportDate,'-01 00:00:00') reportDate, IFNULL(Irradiance, 0), a.AC1V, a.AC1A, a.AC1W, a.AC1F, a.AC1WH, a.AC2V, a.AC2A, a.AC2W, a.AC2F, a.AC2WH,
|
||
a.AC3V, a.AC3A, a.AC3W, a.AC3F, a.AC3WH, a.DC1V, a.DC1A, a.DC1W, a.DC1WH, a.DC2V, a.DC2A, a.DC2W, a.DC2WH, a.DC3V, a.DC3A, a.DC3W,
|
||
a.DC3WH, a.DC4V, a.DC4A, a.DC4W, a.DC4WH, a.DC5V, a.DC5A, a.DC5W, a.DC5WH, a.PR, a.RA1, a.RA2, a.RA3, a.RA4, a.RA5, DCKW, ACKW, a.KWH, a.TODAYKWH, a.TOTALKWH,
|
||
(a.KWH / i.Capacity) AS KWHKWP
|
||
from
|
||
( -- 取得該時間區間的KWH
|
||
SELECT DATE_FORMAT(a.TIMESTAMP, '%Y-%m') AS reportDate, a.INVERTERID,
|
||
AVG(a.AC1V) AS AC1V, AVG(a.AC1A) AS AC1A, SUM(a.AC1W) AS AC1W, AVG(a.AC1F) AS AC1F, SUM(a.AC1WH) AS AC1WH, AVG(a.AC2V) AS AC2V,
|
||
AVG(a.AC2A) AS AC2A, SUM(a.AC2W) AS AC2W, AVG(a.AC2F) AS AC2F, SUM(a.AC2WH) AS AC2WH,AVG(a.AC3V) AS AC3V, AVG(a.AC3A) AS AC3A,
|
||
SUM(a.AC3W) AS AC3W, AVG(a.AC3F) AS AC3F, SUM(a.AC3WH) AS AC3WH, AVG(a.DC1V) AS DC1V, AVG(a.DC1A) AS DC1A, SUM(a.DC1W) AS DC1W,
|
||
SUM(a.DC1WH) AS DC1WH, AVG(a.DC2V) AS DC2V, AVG(a.DC2A) AS DC2A, SUM(a.DC2W) AS DC2W, SUM(a.DC2WH) AS DC2WH, AVG(a.DC3V) AS DC3V,
|
||
AVG(a.DC3A) AS DC3A, AVG(a.DC3W) AS DC3W, AVG(a.DC3WH) AS DC3WH, AVG(a.DC4V) AS DC4V, AVG(a.DC4A) AS DC4A, SUM(a.DC4W) AS DC4W,
|
||
SUM(a.DC4WH) AS DC4WH,AVG(a.DC5V) AS DC5V, AVG(a.DC5A) AS DC5A, SUM(a.DC5W) AS DC5W, SUM(a.DC5WH) AS DC5WH, avg(PR) AS PR,
|
||
AVG(a.RA1) AS RA1, AVG(a.RA2) AS RA2, AVG(a.RA3) AS RA3, AVG(a.RA4) AS RA4, AVG(a.RA5) AS RA5, avg(DCKW) as DCKW, avg(ACKW) as ACKW,
|
||
avg(a.TODAYKWH) AS TODAYKWH, MAX(a.TOTALKWH) AS TOTALKWH, SUM(a.KWH) AS KWH
|
||
FROM solar_master.inverter_history_day a
|
||
WHERE powerstationID = @powerstationID and DATE_FORMAT(a.TIMESTAMP, '%Y-%m') = @date1
|
||
GROUP BY DATE_FORMAT(a.TIMESTAMP, '%Y-%m'), a.INVERTERID
|
||
) a
|
||
LEFT JOIN " + _siteDB + @".inverter i ON a.INVERTERID = i.InverterId
|
||
-- 取日照度 ----------------------
|
||
left join (
|
||
select DATE_FORMAT(a.TIMESTAMP, '%Y-%m') AS reportDate, Irradiance
|
||
from sensor_history_month a
|
||
where powerstationID = @powerstationID and DATE_FORMAT(a.TIMESTAMP, '%Y-%m') = @date1 and Irradiance <> 0
|
||
)irr on a.reportDate = irr.reportDate ;";
|
||
conn.Execute(sql, new { date1 = _date1.Substring(0, 7), PowerStationID = _powerStationID });
|
||
|
||
if (_logger != null)
|
||
{
|
||
_logger.LogInformation("【ProcInvSvc】執行完成[{0}]在{1}逆變器month補償", _siteID, _date1);
|
||
}
|
||
}
|
||
catch (Exception ex)
|
||
{
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器month補償", _siteID, _date1);
|
||
_logger.LogError("【ProcInvSvc】執行失敗[{0}]在{1}逆變器month補償 - [Exception]:{2}", _siteID, _date1, ex.ToString());
|
||
throw ex;
|
||
}
|
||
|
||
#endregion month
|
||
|
||
conn.Close();
|
||
}
|
||
result = true;
|
||
}
|
||
catch (Exception ex)
|
||
{
|
||
throw ex;
|
||
}
|
||
return result;
|
||
}
|
||
}
|
||
}
|